Selank is a hydrophilic peptide and dissolves readily in water and in aqueous buffers. The lyophilised powder is typically a white to off-white solid. Because short peptides are prone to hydrolysis and oxidation, handling benefits from limiting exposure to heat, moisture and strong light. Working solutions are commonly prepared in sterile water or saline, and repeated freeze-thaw cycles are avoided to reduce aggregation and loss of activity. These practices reflect general laboratory convention rather than published stability specifications.

Dry powder is normally held at -20 degrees Celsius or lower, in a sealed container with desiccant and protection from light. Reconstituted solutions are usually kept at 2 to 8 degrees Celsius for short periods and frozen for longer ones. Proline residues at several positions are generally associated with some resistance to peptidase attack, but chemical stability still declines at neutral to alkaline pH and at elevated temperature. Exact shelf-life figures are product-specific and are not standardised across suppliers.

Selank Handling, Stability, and Analysis

Once dissolved, the peptide is markedly less stable than the dry powder. Aqueous solutions are subject to backbone hydrolysis and to microbial growth when they are handled without sterile technique. Buffered solutions near neutral pH are common for short-term laboratory work, while acidic conditions are sometimes used to improve solubility. Analytical laboratories generally prepare working solutions fresh rather than storing them, and a residual water film left in a reopened vial can seed degradation even when the container appears dry.

Reversed-phase high-performance liquid chromatography is the standard technique for estimating peptide purity. The result is a peak-area percentage, which describes how much of the detected material elutes as the main peak in one run. Mass spectrometry confirms the molecular mass and can reveal truncated, adducted, or otherwise modified species. Amino acid analysis or tandem mass spectrometry can address sequence fidelity when identity is in doubt. None of these measurements, taken alone, establishes that a sample is fit for any specific purpose.

Lyophilized selank is normally supplied as a dry powder and is considered stable for extended periods when kept cold and dry. Moisture uptake is the main practical threat, because absorbed water promotes both hydrolysis and aggregation in the solid state. Vials are usually warmed to room temperature before opening so that condensation does not form on the powder. Supplier documentation commonly specifies -20 °C for routine storage, with -80 °C used for material intended to be archived for years.

Selank at a glance

PropertyValueNotes
AppearanceWhite to off-white powderLyophilised solid form
Solubility classFreely soluble in waterHydrophilic heptapeptide
Dry storage temperature-20 degrees Celsius or lowerSealed, desiccated, protected from light
Solution storage2 to 8 degrees Celsius short termAvoid repeated freeze-thaw cycles
Common identification methodReversed-phase HPLC with mass spectrometryConfirms purity and molecular mass

Proposed Mechanisms and Research Endpoints

Selank is studied chiefly as an animal-model anxiolytic with proposed secondary effects on memory and immune signaling. Reported mechanisms include modulation of the GABA-A receptor complex, inhibition of enkephalin-degrading enzymes, and shifts in monoamine turnover within limbic structures. Some experiments describe increased expression of brain-derived neurotrophic factor in the hippocampus after repeated dosing. No single molecular target has been confirmed, and the peptide does not bind any receptor with the selectivity typical of a conventional small-molecule drug. Mechanism therefore remains a set of hypotheses rather than an established pathway.

Laboratory work relies on standard behavioral paradigms. Rodents are tested in the elevated plus maze, open field, and passive avoidance tasks, with outcomes compared against diazepam or vehicle controls. Intranasal dosing is used most often because it bypasses first-pass metabolism, though intraperitoneal and intravenous routes also appear in published protocols. Biochemical endpoints include tissue BDNF concentrations, cytokine levels, and monoamine metabolites. Human data are limited to small Russian trials reporting reduced anxiety scores; most were not prospectively registered, and few employed independent outcome assessment.

Measuring peptide exposure inside the brain is technically difficult. Selank is degraded rapidly in plasma, and assays must separate intact peptide from fragments, which favors targeted mass spectrometry over immunoassays alone. Reported half-lives are short, on the order of minutes, so effects observed hours later are attributed to downstream signaling rather than to the parent compound. Blood-brain barrier permeability is debated and rarely quantified directly. Gaps include absent dose-response characterization, inconsistent reporting of purity, and almost no pharmacokinetic data from human participants.

Related pages on this site

Analytical Methods and Stability

Identity and purity of selank are established with reversed-phase high-performance liquid chromatography coupled to mass spectrometry. The peptide elutes from C18 columns with acetonitrile gradients in water containing trifluoroacetic acid or formic acid, and detection is usually performed by ultraviolet absorbance near 214 nm. Electrospray ionization in positive mode gives a doubly protonated ion near m/z 377, consistent with a mass of about 752 Da. Amino acid analysis or tandem mass spectrometry of fragment ions confirms the sequence. Because the molecule has no aromatic residues, it lacks a usable 280 nm chromophore, so low-wavelength detection or mass spectrometry is required.

Peptide bonds in selank are susceptible to hydrolysis under strongly acidic or basic conditions, and the terminal proline residues are vulnerable to exopeptidase activity in biological samples. Lyophilized powder stored dry at -20 °C typically remains stable for extended periods, whereas aqueous solutions degrade faster and may lose measurable purity within days to weeks depending on pH, temperature, and microbial load. Repeated freeze-thaw cycles promote aggregation and adsorption to container surfaces. For analytical work, solutions are usually prepared fresh, kept cold, and used within a single working day.

Handling follows standard practice for research peptides. Material is weighed in a low-humidity environment because the powder absorbs atmospheric moisture. Purity is reported as the percentage area of the main peak in a chromatogram, with specifications commonly set at 95 percent or higher; values below that threshold indicate the presence of truncated or modified species. Residual trifluoroacetate from purification is often present and may affect mass balance. Certificates of analysis should state the analytical method, the column and gradient used, and the lot-specific retention time so that results can be compared across suppliers.

Analytical Methods and Handling

Lyophilized Selank, the dry powder form, is generally stored frozen at minus 20 degrees Celsius or colder for long-term keeping. The solid is hygroscopic and should stay sealed, dry, and protected from light. Once dissolved, the peptide is less stable and is usually held refrigerated at 2 to 8 degrees Celsius for short periods. Repeated freezing and thawing is avoided because it can promote aggregation and loss of activity. Buffers and pH choice also affect how long a solution remains usable.

Solubility behavior is a practical concern for handling. Selank dissolves readily in water and in common aqueous buffers, which simplifies preparation of working solutions. The choice of solvent, ionic strength, and pH can influence aggregation over time, particularly at higher concentrations. Aqueous solutions are typically sterile-filtered before use. Because stability depends on several variables, storage and handling notes should be treated as general guidance rather than fixed rules, and specific values are best confirmed against a certificate of analysis for each batch.

Background and Molecular Identity

Selank is a synthetic heptapeptide with the sequence Thr-Lys-Pro-Arg-Pro-Gly-Pro. Its four N-terminal residues reproduce tuftsin, a tetrapeptide fragment of the immunoglobulin heavy chain, while the C-terminal Pro-Gly-Pro extension is a synthetic addition. The peptide has a molecular mass near 752 daltons and carries a net positive charge at physiological pH because of the arginine and lysine side chains. Published indexes list it under the name Selank and the sequence abbreviation TKPRPGP. Solid-phase peptide synthesis is the standard production route for research quantities.

Development took place at the Institute of Molecular Genetics of the Russian Academy of Sciences, where a series of short peptides were designed in the 1980s and 1990s. Selank was selected from variants of tuftsin that showed resistance to plasma peptidases. Russian regulatory approval covers it as an anxiolytic agent given intranasally. Outside that market the compound is normally handled as a research chemical rather than a medicine, and no widely recognised international pharmacopoeial monograph exists. The name Selank is a coined trade designation rather than a systematic chemical name.

Enzymatic stability motivates the extra three residues at the carboxyl end. Native tuftsin is cleaved quickly by circulating aminopeptidases and carboxypeptidases, which limits its duration of action and its usefulness as a tool compound. Extending the chain with proline-rich segments is a common design tactic because proline constrains the backbone and slows proteolysis. The same Pro-Gly-Pro motif appears in other Russian-developed peptides of the era. Whether the full seven-residue chain is required for activity, or whether it acts mainly as a prodrug releasing tuftsin, remains unresolved.

Reference notes

== Structure == The molecule is a 6-membered ring of alternating nitrogen and sulfur atoms, where each sulfur atom is attached to one chlorine atom by a single bond. The molecule contains alternating single and double bonds in the S3N3 core. The molecule has C3v symmetry. The S3N3 core is slightly ruffled structure with S-N distances of 160.5 pm. The S-Cl distances are 208 pm, and the chlorine atoms are mutually cis. The S centers are tetravalent and pyramidal. In contrast, with six fewer electrons, cyanuric chloride is a planar ring.

Pat Striker (パトストライカー, Pato Sutoraikā): Deka Red's personal six-wheeled, police car-themed Deka Machine that forms the head and torso of Dekaranger Robo. It is also equipped with a pair of Striker Arms (ストライカーアーム, Sutoraikā Āmu), which allows it to wield the Judgement Sword (ジャッジメントソード, Jajjimento Sōdo) in its Driving Sword (ドライビングソード, Doraibingu Sōdo) formation. Pat Gyrer (パトジャイラー, Pato Jairā): Deka Blue's personal autogyro-themed Deka Machine that forms the left leg of Dekaranger Robo. It is also equipped with the Gyro Vulcan (ジャイロバルカン, Jairo Barukan) Gatling guns, the Gyro Wapper (ジャイロワッパー, Jairo Wappā) handcuffs, and the Magnet Wire (マグネワイヤー, Magune Waiyā). PaTrailer (パトレーラー, Patorērā): Deka Green's personal armored semi-trailer truck-themed Deka Machine that forms the right leg of Dekaranger Robo. It also carries the Judgement Sword and the Signal Cannon (シグナルキャノン, Shigunaru Kyanon) into battle. Pat Armor (パトアーマー, Pato Āmā): Deka Yellow's personal armored car-themed Deka Machine that forms the right arm of Dekaranger Robo. It is also equipped with floodlights, which allow it to perform the Armor Attack (アーマーアタック, Āmā Atakku) and Light Flash (ライトフラッシュ, Raito Furasshu) attacks. Pat Signer (パトシグナー, Pato Shigunā): Deka Pink's personal buggy-themed Deka Machine that forms the left arm of Dekaranger Robo. It is also equipped with a large retractable signboard.

=== Partnerships === In 2017, the company announced partnerships with major pharmaceutical companies to negotiate lowering prescription drug costs. GoodRx has deep relationships with major pharmacy chains, including Walgreens, Walmart, CVS Caremark, and Publix, to allow customers to use GoodRx discounts and Gold benefits. GoodRx began its partnership with CVS Caremark in July 2023 to automatically apply coupons to insured CVS customers purchasing generic prescriptions at certain locations. In April 2024, GoodRx added Publix into its network, allowing GoodRx Gold members to use their cards at Publix Pharmacies. GoodRx partners with Pharmacy Benefit Management like Caremark, Express Scripts, and MedImpact to apply their savings directly to eligible insurance plans and members. GoodRx partners with companies like Affirm, Benefitfocus, and DoorDash to integrate their services that offer members discounts and financial flexibility for prescriptions. GoodRx also partners with organizations like the American Academy of Family Physicians Foundation to support broader access to care. In October 2022, GoodRx launched Provider Mode, which allows healthcare providers to use the app to compare costs of drugs for patients based on different payment methods and drug alternatives. In 2025, GoodRx partnered with Novo Nordisk to offer discounted cash-pay access to semaglutide products like Ozempic and Wegovy through its platform and participating pharmacies.

Progesterone (P4), sold under the brand name Prometrium among others, is a medication and naturally occurring steroid hormone. It is a progestogen and is used in combination with estrogens mainly in hormone therapy for menopausal symptoms, and low sex hormone levels in women, as well as gender affirming therapy in transgender women. It is also used in women to support pregnancy and fertility and to treat gynecological disorders. Progesterone can be taken by mouth, vaginally, and by injection into muscle or fat, among other routes. A progesterone vaginal ring and progesterone intrauterine device used for birth control also exist in some areas of the world. Progesterone is well tolerated and often produces few or no side effects. However, a number of side effects are possible, for instance mood changes. If progesterone is taken by mouth or at high doses, certain central side effects including sedation, sleepiness, and cognitive impairment can also occur. The medication is a naturally occurring progestogen and hence is an agonist of the progesterone receptor (PR), the biological target of progestogens like endogenous progesterone. It opposes the effects of estrogens in various parts of the body like the uterus and also blocks the effects of the hormone aldosterone. In addition, progesterone has neurosteroid effects in the brain. Progesterone was first isolated in pure form in 1934. It first became available as a medication later that year. Oral micronized progesterone (OMP), which allowed progesterone to be taken by mouth, was introduced in 1980.

Sources: en.wikipedia.org

Reference notes

=== Measurement and invalidation of ORAC === Measurement of polyphenol and carotenoid content in food is not a straightforward process, as antioxidants collectively are a diverse group of compounds with different reactivities to various ROS. In food science analyses in vitro, the oxygen radical absorbance capacity (ORAC) was once an industry standard for estimating antioxidant strength of whole foods, juices and food additives, mainly from the presence of polyphenols. Earlier measurements and ratings by the United States Department of Agriculture were withdrawn in 2012 as biologically irrelevant to human health, referring to an absence of physiological evidence for polyphenols having antioxidant properties in vivo. Consequently, the ORAC method, derived only from in vitro experiments, is no longer considered relevant to human diets or biology, as of 2010. Alternative in vitro measurements of antioxidant content in foods – also based on the presence of polyphenols – include the Folin-Ciocalteu reagent, and the Trolox equivalent antioxidant capacity assay.

==== MeSH E05.200.249 – culture techniques ==== MeSH E05.200.249.249 – cell culture techniques MeSH E05.200.249.374 – coculture techniques MeSH E05.200.249.437 – diffusion chambers, culture MeSH E05.200.249.468 – embryo culture techniques MeSH E05.200.249.484 – organ culture techniques MeSH E05.200.249.617 – tissue culture techniques MeSH E05.200.249.750 – tissue engineering

== Metrics == The following are the most commonly measured pharmacokinetic metrics: The units of the dose in the table are expressed in moles (mol) and molar (M). To express the metrics of the table in units of mass, instead of amount of substance, simply replace 'mol' with 'g' and 'M' with 'g/L'. Similarly, other units in the table may be expressed in units of an equivalent dimension by scaling.

Sources: en.wikipedia.org

Notes from published material

Reference Model of Open Distributed Processing (RM-ODP) is a reference model in computer science, which provides a co-ordinating framework for the standardization of open distributed processing (ODP). It supports distribution, interworking, platform and technology independence, and portability, together with an enterprise architecture framework for the specification of ODP systems. RM-ODP, also named ITU-T Rec. X.901-X.904 and ISO/IEC 10746, is a joint effort by the International Organization for Standardization (ISO), the International Electrotechnical Commission (IEC) and the Telecommunication Standardization Sector (ITU-T).

Fast CFDs of advanced designs have the dead times equal to or less than two single-hit response times of the ion detector (single-hit response time for MCP with 2-5 micron wide channels can be somewhere between 0.2 ns and 0.8 ns, depending on the channel angle) thus preventing repetitive triggering from the same pulse. Double-hit resolution (dead time) of modern multi-hit TDC can be as low as 3-5 nanosecond. The TDC is a counting detector – it can be extremely fast (down to a few picosecond resolution), but its dynamic range is limited due to its inability to properly count the events when more than one ion simultaneously (i.e., within the TDC dead time) hit the detector. The outcome of limited dynamic range is that the number of ions (events) recorded in one mass spectrum is smaller compared to real number. The problem of limited dynamic range can be alleviated using multichannel detector design: an array of mini-anodes attached to a common MCP stack and multiple CFD/TDC, where each CFD/TDC records signals from individual mini-anode. To obtain peaks with statistically acceptable intensities, ion counting is accompanied by summing of hundreds of individual mass spectra (so-called hystograming). To reach a very high counting rate (limited only by duration of individual TOF spectrum which can be as high as few milliseconds in multipath TOF setups), a very high repetition rate of ion extractions to the TOF tube is used. Commercial orthogonal acceleration TOF mass analyzers typically operate at 5–20 kHz repetition rates.

There was a 1922 model that consisted of a wooden cold box, water-cooled compressor, an ice cube tray and a 0.25-cubic-metre (9 cu ft) compartment, and cost $714. (A 1922 Model-T Ford cost about $476.) By 1923, Kelvinator held 80 percent of the market for electric refrigerators. Also in 1923 Frigidaire introduced the first self-contained unit. About this same time porcelain-covered metal cabinets began to appear. Ice cube trays were introduced more and more during the 1920s; up to this time freezing was not an auxiliary function of the modern refrigerator.

Sources: en.wikipedia.org

Frequently asked questions

How should the powder be stored?

Dry powder is normally held at -20 degrees Celsius or below in a sealed, light-protected container with desiccant. Brief room-temperature handling during weighing is generally tolerated. Storage instructions vary between suppliers, so the accompanying certificate of analysis should be followed.

How is identity confirmed?

Reversed-phase HPLC establishes purity, while mass spectrometry confirms the expected molecular mass. Sequence confirmation may use tandem mass spectrometry or peptide mapping. A certificate of analysis typically reports these results alongside the analytical method applied.

Is it legal to purchase?

In Russia it is a registered medicine available by prescription. In many other countries it is not approved for human use and is supplied only as a research chemical. Import and possession rules differ by jurisdiction, and buyers are responsible for checking local requirements.

How should selank powder be stored?

Sealed, desiccated storage at -20 °C or colder is the standard recommendation for research-grade material. Vials should reach room temperature before they are opened, which limits condensation. Repeated temperature cycling is discouraged.